Typically two cores per 1200mm wide slab are formed open so that a reinforcement bar can be inserted across the slabs.
Concrete floor slab to masonry block detail.
This tek contains details for various types of concrete masonry foundation walls with accompanying text as appropriate.
The slab is constructed on well compacted granular fill crushed stone or marl.
The details are developed by imi s technical team of architects and engineers and are reviewed by international masonry.
Proprietary systems that use concrete masonry units as a filler between the steel joists are also available.
The information and technical details provided correlate with all legislative requirements and generally accepted good trade practice.
Concrete slabs can take many forms including prestressed precast and cast in place construction.
The top steel reinforcement is important.
The reader is referred to tek 3 11 concrete masonry basement wall construction tek 19 3b preventing water penetration in below grade concrete masonry walls and ncma s basement manual for more detailed design and.
Roof detail pitched roof to high wall 01 030 0751.
Shelf angle detail anchored brick veneer cmu backing shelf angle with bracket type standoffs 01 030 0721.
The mesh reinforcement in the slab is placed in the top with 1 covers.
140 mm blocks or a 90 mm and 190 mm block.
The cores on opposing slabs need to.
This compilation includes hundreds of details for brick block and stone masonry systems as well as details for ceramic tile marble terrazzo plaster rainscreen systems terra cotta aac and masonry restoration.
Detail 1 3a brick veneer concrete block detail at slab edge for load bearing wall detail 1 4 brick veneer concrete block detail at slab edge detail 1 5 membrane air barrier detail at movement joint.
Roof detail high wall low roof.
4 2 slab on grade construction details.
The suspended reinforced concrete slab is tied into the external capping beam at floor level.
Figures 4 12 through 4 14 show variations where the slab is the primary location for insulation.
Figures 4 9 through 4 11 and 4 15 show configurations with insulation on the exterior surface of the foundation.
Details of concrete masonry 5 cavity walls 240 mm to 290 mm reference c computer.
The cores are then filled with in situ concrete to form the tie detail.
Alternative floor slab detail.
In this section several typical slab on grade sections are illustrated and described.
Although provided as a guide only common sense and job specific detailing can be added by qualified designers.
Steel bar joists typically use pocketed or ledger connections to concrete masonry walls.