The higher the r value the better the thermal performance of the insulation.
Continuous insulation on attic eave wall.
Ensure meets any eaves insulation and or internal wall insulation to prevent cold bridge at eaves without blocking any ventilation paths required to loft space roof space.
You can achieve better thermal performance in your attic by adding an additional layer of insulation.
Insulation cover should be even and continuous right to the eaves.
Design the roof with raised heel trusses to allow full insulation over the top plates of the exterior walls.
Baffles placed in this area channel intake air into either the attic space or vent chutes and also prevent insulation from falling into the soffit and blocking airflow.
If you re considering turning your attic into conditioned storage or living space it s worth changing tactics to insulate between the rafters and wall joists instead of the floor.
If you have vermiculite in your attic don t disturb it unless you have a sample checked by an accredited laboratory.
The space above the top plate of exterior walls at the bottom of each rafter bay is especially important.
Asbestos has been found in some types of vermiculite insulation.
You can use rigid foam panels or do as tom silva does with nearly all houses these days.
85 minimum to bs en iso 14021.
Pa302 2 ceilings without attic spaces n1102 2 2 r402 2 2.
Install raised heel trusses or use another roof framing method that allows space to install insulation over the top plates of the exterior walls or install high density insulation to achieve an r value that meets or exceeds code minimums for attic insulation.
Achieving greater r values in exterior walls in exterior walls add insulating sheathing to achieve a greater r value in your wall system.
Hire a pro to install spray foam insulation.
Unlike typical insulation installed between framing members continuous insulation provides an uninterrupted thermal barrier for unparalleled performance.
Applications of continuous insulation.
Continuous insulation products can also serve as the water resistant barrier and air barrier for a structure providing a 3 in 1 building envelope solution.
Where the design of the roof ceiling assembly does not allow sufficient space for the required insulation such as cathedral ceilings the minimum required insulation for such roof ceiling assemblies shall be r 30.
An attic s intake vents are most commonly installed directly in the soffit either as individual vents spaced every few feet or as one continuous perforated soffit running the entire length of.
Flexible formaldehyde free glass mineral wool.
R 38 shall be deemed to satisfy the requirement for r 49 wherever the full height of uncompressed r 38 insulation extends over the wall top plate at the eaves.